TRF7970A
SLOS743K – AUGUST 2011 – REVISED APRIL 2014
www.ti.com
Communication is initialized by a start condition, which is expected to be followed by an
Address/Command word (Adr/Cmd). The Adr/Cmd word is 8 bits long, and Table 6-11 shows its format.
Table 6-11. Address and Command Word Bit Distribution
Bit
B7
B6
B5
B4
B3
B2
B1
B0
Description
Command control bit
Read/Write
Continuous address mode
Address/Command bit 4
Address/Command bit 3
Address/Command bit 2
Address/Command bit 1
Address/Command bit 0
Bit Function
0 = address
1 = command
0 = write
1 = read
1 = Continuous mode
Address
0
R/W
R/W
Adr 4
Adr 3
Adr 2
Adr 1
Adr 0
Command
1
0
0
Cmd 4
Cmd 3
Cmd 2
Cmd 1
Cmd 0
The MSB (bit 7) determines if the word is to be used as a command or as an address. The last two
columns of Table 6-11 show the function of the separate bits if either address or command is written. Data
is expected once the address word is sent. In continuous-address mode (Cont. mode = 1), the first data
that follows the address is written (or read) to (from) the given address. For each additional data, the
address is incremented by one. Continuous mode can be used to write to a block of control registers in a
single stream without changing the address; for example, setup of the predefined standard control
registers from the MCU non-volatile memory to the reader. In non-continuous address mode (simple
addressed mode), only one data word is expected after the address.
Address Mode is used to write or read the configuration registers or the FIFO. When writing more than 12
bytes to the FIFO, the Continuous Address Mode should be set to 1.
The Command Mode is used to enter a command resulting in reader action (for example, initialize
transmission, enable reader, and turn reader on or off).
Examples of expected communications between an MCU and the TRF7970A are shown in the following
sections.
30
Detailed Description
Submit Documentation Feedback
Product Folder Links: TRF7970A
Copyright ? 2011–2014, Texas Instruments Incorporated
相关PDF资料
TRM-418-LT TRANSCEIVER RF 418MHZ LT SERIES
TRM-900-NT RF TXRX 915MHZ NT SERIES
TRX08GVP2540 TXRX OPT SCFF 8.5GB/S 850NM
TS-320240BRNO TCH PANEL 140X104 RESISTIVE MONO
TS-TFT3.5Z TOUCH PANEL 140X1.4.0 TFT
TS3-75B3 SENSOR THERMAL MOXIE NTC 75C
TSL26711FN IC PROXIMITY DETECTOR 6-DFN
TSOP57238TT1 IC IR RCVR MODULE 38KHZ
相关代理商/技术参数
TRF7970ARHBR 功能描述:IC RFID/NFC AFE 13.56MHZ 32QFN RoHS:是 类别:RF/IF 和 RFID >> RFID IC 系列:- 其它有关文件:CR14 View All Specifications 标准包装:1 系列:- RF 型:收发器 频率:13.56MHz 特点:ISO14443-B 封装/外壳:16-SOIC(0.154",3.90mm 宽) 供应商设备封装:16-SO 包装:Digi-Reel® 其它名称:497-5719-6
TRF7970ARHBT 功能描述:IC RFID/NFC AFE 13.56MHZ 32QFN RoHS:是 类别:RF/IF 和 RFID >> RFID IC 系列:- 其它有关文件:CR14 View All Specifications 标准包装:1 系列:- RF 型:收发器 频率:13.56MHz 特点:ISO14443-B 封装/外壳:16-SOIC(0.154",3.90mm 宽) 供应商设备封装:16-SO 包装:Digi-Reel® 其它名称:497-5719-6
TRF7970ATB 功能描述:RFID应答器 TRF7970A Target Brd RoHS:否 制造商:Murata 存储容量:512 bit 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体: 封装:Reel
TRF79A6AA17LB000 制造商:Opnext 功能描述:XFP FORM FACTOR - Boxed Product (Development Kits)
TRF79A6AA18LB000 制造商:Opnext 功能描述:XFP FORM FACTOR - Boxed Product (Development Kits)
TRF79A6AA19LB000 制造商:Opnext 功能描述:XFP FORM FACTOR - Boxed Product (Development Kits)
TRF79A6AA20LB000 制造商:Opnext 功能描述:XFP FORM FACTOR - Boxed Product (Development Kits)
TRF79A6AA21LB000 制造商:Opnext 功能描述:XFP FORM FACTOR - Boxed Product (Development Kits)